LDM 500 for the municipality of Ägeri in the catchment area of the Water Protection Association region Zug

New measurement for accurate data

Precise measurement data for wastewater using transit time difference measurement

The LDM with a nominal width of 500 mm enables the precise and reliable measurement of the flow rate, even at low levels, in the supplied size from 37.9 mm. Flow measurement is carried out with maximum accuracy using ten flow speed measuring sections distributed over the entire cross-section. These are based on the robust and contamination-resistant ultrasonic transit time difference measuring method.

The LDM system is easy to configure via the web interface or directly via the touch panel integrated into the transmitter.

The touch panel provides the system operator with all operating data such as meter readings, status displays, etc. The signal quality of each individual measuring head can also be monitored. The signal quality of each individual measurement path is also recorded and displayed.

Contamination report reduces cleaning work

With the transit time difference method, the different transit times of ultrasonic measurement signals in the direction of flow and against the direction of flow of the medium are analysed, whereby the signal quality power is automatically increased in the event of contamination. If the transmission power exceeds a certain level, system cleaning is requested via the interface before measurement errors occur.

Easy installation and commissioning

The installation and commissioning of the measuring point was simple, as the system was screwed into the pipework in a time-saving manner using prepared tie rods and the sensors had already been calibrated in STEBATEC’s in-house hydraulic laboratory.

The robust and contamination-resistant system, which also has excellent properties against abrasion, minimises maintenance and service costs. There is ample service access in the immediate vicinity of the measuring point for any maintenance work that may be required.

About the Water Protection Association region Zug

In the catchment area of the Water Protection Association Region Zug, to which 17 municipalities belong, a sewer network with around 85 km of collecting sewers, 22 pumping stations and 12 stormwater overflow basins was built.

The Schönau WWTP and the association’s pipe network with the outdoor facilities are managed by a 26-strong team.

Products in use

Ultrasonic transit time difference flow measurement for wastewater, raw wastewater and rainwater
Highly precise flow value acquisition. The LDM is a calibrated measuring device for backflow-free flow measurement of waste water in open channels or free flowing lines. 10 flow velocity measuring sections distributed over the entire cross section provide most accurate flow values when the sensor is partially or fully filled. The level measurement is integrated in the device housing.
Proud of our craft!
Day after day, STEBATEC fitters honour our craft by carrying out installations of the highest quality that are a joy to the eye of the professional.
Preventive maintenance, servicing, spare parts management and many other services to ensure the reliability of automation systems.
Whether it is the cleaning of systems or the replacement of mechanical wear parts, the monitoring of functions, the calibration of measuring instruments or software updates, whenever customers need support in the ideal operation and maintenance of a system from our company, we are available with our services.

Feedback

«Stebatec impresses us with its innovations and good service. We particularly appreciate the co-operation with Stebatec's motivated employees, who work with us persistently to find the best solution.»
Fabrice Bachmann
Managing Director GVRZ